Microgrids engineered for 20 kW to 50 MW

Lock Hill designs, builds, commissions and maintains microgrids engineered for 20 kW to 50 MW. One point of accountability, from the single-line through long-term service.

Lock Hill Energy Services Ltd. is a licensed Alberta electrical contractor based in Nisku. We deliver microgrids for oil and gas, industrial, data center, remote and off-grid, and infrastructure sites across Western Canada, the Northwest Territories and Yukon.

We are equipment-agnostic. We integrate the generation, storage and controls platform that fits the project, or the one the owner has already selected. Scope covers natural gas and diesel generation, paralleled and islanded; BESS; solar PV; LV and MV switchgear, protection and controls up to 34.5 kV; and SCADA. Topologies include grid-tied, islanded and zero-export, with utility interconnection support.

Canadian work references CSA C22.1, CSA C22.3 No. 9, AUC and Alberta Micro-generation and DER rules. U.S. projects reference NEC Art. 705/706, IEEE 1547, IEEE 2030.7/2030.8, UL 9540/9540A and ERCOT. Commissioning includes load bank testing up to 5 MW. Field service runs 24/7, with a 1-hour call-back.

What We Deliver

Natural gas and diesel generation

We supply, parallel and commission natural gas and diesel generation for grid-tied and islanded operation.

Sets can run as a single unit or as a paralleled plant, with protection and controls tied into the microgrid.

BESS integration

We integrate battery energy storage for grid-forming or grid-following duty, black start and load step support.

The storage platform is selected for the project, or we integrate the system the owner has already specified.

Solar PV tie-in

We tie solar PV into the microgrid at the switchgear and controls layer.

Export can be limited or set to zero where the interconnection requires it.

Switchgear, protection and controls

We install and integrate LV and MV switchgear, protection and controls on systems up to 34.5 kV.

Control panels are built in our Nisku shop and released under Intertek special inspection, one panel at a time.

SCADA, topologies and interconnection

We do PLC, SCADA and HMI work in-house, including Modbus and CAN J1939.

We support utility interconnection for grid-tied, islanded and zero-export topologies.

Commissioning, testing and service

We commission the system, including load bank testing up to 5 MW.

Preventive maintenance and load bank reports follow CSA C282, and emergency service runs 24/7, with a 1-hour call-back at 780-387-6119.

Built to Scale

20 kW–500 kW

Typical architecture: Solar + storage + standby generator.

Voltage class: LV to 600 V.

Applications: Remote sites, telecom, edge data, small commercial.

500 kW–5 MW

Typical architecture: Paralleled gensets + BESS, with optional solar PV tie-in.

Voltage class: LV/MV up to 4.16 kV.

Applications: Industrial facilities, oil and gas sites, camps, critical infrastructure.

5 MW–50 MW

Typical architecture: Multi-unit paralleled natural gas or diesel generation + BESS, with MV distribution.

Voltage class: MV, 4.16–34.5 kV.

Applications: Behind-the-meter data center and large industrial.

Why Lock Hill

Single point of accountability

One contractor owns the work from the single-line diagram through construction, commissioning and long-term service.

You are not coordinating a designer, a generator vendor, a battery vendor and a service contractor to keep one system running.

Equipment-agnostic integration

We do not lock the project to one OEM.

We integrate the generation, storage and controls platform that fits the project, or the platform the owner has already selected.

Licensed electrical contractor, in-house controls

Lock Hill is a licensed Alberta electrical contractor. We pull our own permits and install to the Canadian Electrical Code. PLC, SCADA and HMI work is done in-house.

Control panels are built in our Nisku shop and released under Intertek special inspection, one panel at a time. We work on systems up to 34.5 kV.

Commissioning and 24/7 service

We commission what we build, including load bank testing up to 5 MW. Preventive maintenance and load bank reports follow CSA C282.

Crews include journeyman and master electricians and heavy equipment technicians. Emergency service runs 24/7, with a 1-hour call-back. Lock Hill is ISNetworld prequalified and a CCIB Certified Indigenous Business.

Specifications by tier

20 kW–500 kW 500 kW–5 MW 5 MW–50 MW
Capacity 20 kW–500 kW 500 kW–5 MW 5 MW–50 MW
Voltage LV to 600 V LV/MV up to 4.16 kV MV, 4.16–34.5 kV
Fuel types Natural gas, diesel Natural gas, diesel Natural gas, diesel
Storage BESS with solar and a standby generator BESS with paralleled gensets BESS with multi-unit paralleled gas or diesel generation
Controls LV protection and controls; SCADA (Modbus, CAN J1939) Paralleling, LV/MV protection and controls; SCADA MV protection and controls; plant-level SCADA
Standards Canadian work references CSA C22.1, CSA C22.3 No. 9, AUC and Alberta Micro-generation and DER rules. U.S. projects reference NEC Art. 705/706, IEEE 1547, IEEE 2030.7/2030.8, UL 9540/9540A and ERCOT. Same Canadian and U.S. project references. Same Canadian and U.S. project references.

Frequently asked questions

What size of microgrid does Lock Hill work on?

Lock Hill designs, builds, commissions and maintains microgrids engineered for 20 kW to 50 MW. Work covers remote and telecom sites, industrial and oil and gas facilities, camps, critical infrastructure, and behind-the-meter data center power.

Does Lock Hill specify a single generator or battery brand?

No. Lock Hill is equipment-agnostic. We integrate the generation, storage and controls platform that fits the project, or the platform the owner has already selected.

Where does Lock Hill deliver microgrid work?

Lock Hill is based in Nisku, Alberta, and serves Western Canada, the Northwest Territories and Yukon.

What standards do Lock Hill microgrids reference?

Canadian work references CSA C22.1, CSA C22.3 No. 9, AUC and Alberta Micro-generation and DER rules. U.S. projects reference NEC Art. 705/706, IEEE 1547, IEEE 2030.7/2030.8, UL 9540/9540A and ERCOT. Preventive maintenance and load bank reports follow CSA C282.

Do you commission, test and service the microgrid after it is built?

Yes. Lock Hill commissions the system, including load bank testing up to 5 MW. Preventive maintenance and load bank reports follow CSA C282. Field service runs 24/7, with a 1-hour call-back at 780-387-6119.

Talk to us about a microgrid

Tell us the load, the site constraints and any generation or storage already specified. We will scope the electrical, controls and service package.